First of all, thank you for purchasing our company's microcomputer temperature controller. This product brings together a wide range of modern heating and cooling technologies, with the advantages of small size, simple operation, accurate temperature measurement and strong anti-interference ability. It is suitable for most users to use various automatic and intelligent control systems for various refrigeration and heating equipment in different environments. The cooling and heating modes can be set through menus and have the function of setting parameters and power-off permanent memory.
 
Specifications:
1. The working voltage is referenced on the product casing;
2. -40°C ~120°C: Measurement error ± 0. 5 ° C
3. -40°C~120°C: Temperature control accuracy: 1°C display accuracy 0. 1°C
4. NTC25°C=10K B3435 1% soil (1 meter long, regardless of positive or negative)
5. Power supply voltage: DC version is DC12~72V, AC version is AC100/220V
6. Working environment: Temperature: -20 ° C ~ 70 ° C, humidity: 90% RH no condensation
7. Product size: 75*85*35 (width, depth and height) mm
 
Instructions:
Mode setting: Press and hold the S key for 3 seconds to enter the program menu code mode, which displays the current code "HC" and the code value "H". Press the S key to cycle through the HC-CP-LA-HA-PU-CA parameter code. Press the △ or ▽ key to change the value of the code. After the operation is stopped for 5 seconds, the parameter will be automatically saved and exited. (Press and hold the △ or ▽ key for 2 seconds to quickly adjust the value)
Control temperature setting: Short press S key (not more than 2 seconds) to display the factory default control temperature. Press △ or ▽ key to change the value. After 5 seconds of stop operation, the parameters will be saved automatically and exited. (Press and hold the △ or ▽ key for 2 seconds to quickly adjust the value)
 
Heating control:
When the temperature control method (code HC) is set to H, for example, the set control temperature value is 28 ° C, and the temperature difference is 2 ° C. When the ambient temperature value ≥ the set temperature value (28 °C), the relay opens and closes the output load; when the ambient temperature value ≤ the set temperature value (28 ° C) - the return temperature (2 ° C) and the "delay" is set After the start time, the relay pulls up to start the output load; (if the delay function is not needed, the delay start (code PU) can be set to 0)
 
Cooling mode:
When the temperature control method (code HC) is set to C, for example, the set control temperature value is 28 ° C, and the temperature difference is 2 ° C. When the ambient temperature value ≤ set temperature value (28 °C), the relay opens and closes the output load; when the ambient temperature value ≥ set temperature value (28 °C) + hysteresis temperature (2 °C) and the "delay start" is set After the time, the relay is sucked and the output load is started: (It is recommended that the delay start time is the default time to protect the compressor. If no delay is required, the code (PU) is set to 0)
 
Package:
1 x Dual LED Display Digital Thermostat
1 x Temperature Sensor
X13074 (9) X13074 (10) X13074 (12) X13074 (13) X13074 (14) X13074 (15) X13074 (16)
trust seal
  • guaranteeQuality checked
  • Special gift cardsSpecial gift cards
  • Free return Within 60 days
  • Consultancy86-0755-85201155

MH1220W 10A DC12-72V AC110-220V LED Digital Thermostat Temperature Controller Indoor Outdoor Heating Cooling Thermometer Weather

First of all, thank you for purchasing our company's microcomputer temperature controller. This product brings together a wide range of modern heating and cooling technologies, with the advantages of small size, simple operation, accurate temperature measurement and strong anti-interference ability. It is suitable for most users to use various automatic and intelligent control systems for various refrigeration and heating equipment in different environments. The cooling and heating modes can be set through menus and have the function of setting parameters and power-off permanent memory.
 
Specifications:
1. The working voltage is referenced on the product casing;
2. -40°C ~120°C: Measurement error ± 0. 5 ° C
3. -40°C~120°C: Temperature control accuracy: 1°C display accuracy 0. 1°C
4. NTC25°C=10K B3435 1% soil (1 meter long, regardless of positive or negative)
5. Power supply voltage: DC version is DC12~72V, AC version is AC100/220V
6. Working environment: Temperature: -20 ° C ~ 70 ° C, humidity: 90% RH no condensation
7. Product size: 75*85*35 (width, depth and height) mm
 
Instructions:
Mode setting: Press and hold the S key for 3 seconds to enter the program menu code mode, which displays the current code "HC" and the code value "H". Press the S key to cycle through the HC-CP-LA-HA-PU-CA parameter code. Press the △ or ▽ key to change the value of the code. After the operation is stopped for 5 seconds, the parameter will be automatically saved and exited. (Press and hold the △ or ▽ key for 2 seconds to quickly adjust the value)
Control temperature setting: Short press S key (not more than 2 seconds) to display the factory default control temperature. Press △ or ▽ key to change the value. After 5 seconds of stop operation, the parameters will be saved automatically and exited. (Press and hold the △ or ▽ key for 2 seconds to quickly adjust the value)
 
Heating control:
When the temperature control method (code HC) is set to H, for example, the set control temperature value is 28 ° C, and the temperature difference is 2 ° C. When the ambient temperature value ≥ the set temperature value (28 °C), the relay opens and closes the output load; when the ambient temperature value ≤ the set temperature value (28 ° C) - the return temperature (2 ° C) and the "delay" is set After the start time, the relay pulls up to start the output load; (if the delay function is not needed, the delay start (code PU) can be set to 0)
 
Cooling mode:
When the temperature control method (code HC) is set to C, for example, the set control temperature value is 28 ° C, and the temperature difference is 2 ° C. When the ambient temperature value ≤ set temperature value (28 °C), the relay opens and closes the output load; when the ambient temperature value ≥ set temperature value (28 °C) + hysteresis temperature (2 °C) and the "delay start" is set After the time, the relay is sucked and the output load is started: (It is recommended that the delay start time is the default time to protect the compressor. If no delay is required, the code (PU) is set to 0)
 
Package:
1 x Dual LED Display Digital Thermostat
1 x Temperature Sensor
X13074 (9) X13074 (10) X13074 (12) X13074 (13) X13074 (14) X13074 (15) X13074 (16)