DIN rail box parameters:
  • Product model: UM72
  • Color: green
  • Width: suitable for circuit board width UM72 (inside 72)
  • Insulation grade: flame retardant VO grade
  • Base plate length: suitable for 10 cm circuit boards
  • Net weight: 72 grams
  • Installation method: DIM35 and C45 rail

Features:

  • Working voltage: DC 12V
  • Working current: standby 12MA, 1 relay conduction 40MA, 2 relay conduction 68MA, 3 relay conduction 94MA, 4 relay conduction 120MA, 5 relay conduction 148MA, 6 relay conduction 174MA, 7 Two relays conduct 199MA, 8 relays conduct 224MA
  • Open, close, jog, self-lock, interlock, and delay six working modes
  • MODBUS command (default) and AT command two command control modes
  • The maximum delay under MODBUS command is 255 seconds, the maximum delay under AT command is 9999 seconds
  • AT commands can be input by serial port super terminal (serial assistant); MODBUS commands can be input by "Modbus Poll" besides serial port super terminal input
  • In MODBUS command mode, up to 64 devices can be used in parallel
  • The default baud rate is 9600BPS, you can select the baud rate 2400 4800 19200 BPS through the jumper
  • Size: 100 * 72 * 20mm (circuit board); 120 * 88 * 42mm (with rail box)
  • Weight: 120g (circuit board); 198g (with rail box)
  • Maximum load: 10A/250VAC, 10A/125VAC, 10A/30VDC, 10A/28VDC, 10A/12VDC
trust seal
  • guaranteeQuality checked
  • Special gift cardsSpecial gift cards
  • Free return Within 60 days
  • Consultancy86-0755-85201155
DIN rail box parameters:
  • Product model: UM72
  • Color: green
  • Width: suitable for circuit board width UM72 (inside 72)
  • Insulation grade: flame retardant VO grade
  • Base plate length: suitable for 10 cm circuit boards
  • Net weight: 72 grams
  • Installation method: DIM35 and C45 rail

Features:

  • Working voltage: DC 12V
  • Working current: standby 12MA, 1 relay conduction 40MA, 2 relay conduction 68MA, 3 relay conduction 94MA, 4 relay conduction 120MA, 5 relay conduction 148MA, 6 relay conduction 174MA, 7 Two relays conduct 199MA, 8 relays conduct 224MA
  • Open, close, jog, self-lock, interlock, and delay six working modes
  • MODBUS command (default) and AT command two command control modes
  • The maximum delay under MODBUS command is 255 seconds, the maximum delay under AT command is 9999 seconds
  • AT commands can be input by serial port super terminal (serial assistant); MODBUS commands can be input by "Modbus Poll" besides serial port super terminal input
  • In MODBUS command mode, up to 64 devices can be used in parallel
  • The default baud rate is 9600BPS, you can select the baud rate 2400 4800 19200 BPS through the jumper
  • Size: 100 * 72 * 20mm (circuit board); 120 * 88 * 42mm (with rail box)
  • Weight: 120g (circuit board); 198g (with rail box)
  • Maximum load: 10A/250VAC, 10A/125VAC, 10A/30VDC, 10A/28VDC, 10A/12VDC