40A/100A Spot Welding Machine Dual Pulse Encoder Time Current Control Board

40A/100A Spot Welding Machine Dual Pulse Encoder Time Current Control Board

SKU:YC0009
Regular price $17.99

Reference description:
  • Power supply: AC9-12V 3w 50HZ/60HZ (AC power must be used, DC power cannot be triggered)
  • Starting method: pedal or other passive normally open point (note that it must be a normally open point, and active signals cannot be used)
  • Triggering form: imported optocoupler for SCR
  • Display form: 0.56 digital tube
  • Adjustment method: encoder + button
  • Time range: 1-99
  • Current range: 300-999
  • Welding output: double pulse
  • Voltage stabilization function: Yes
  • Counting function: Yes
  • Power-off save: Yes
  • Number of standard groups: 1 group

Show state description:

  • Common control of the controller3Operation state, welding preparation, parameter query, parameter change
  • Welding preparation:Running light Always Time, current, interval, time, current indicating light out
  • Parameter query:The operation indicates the lights, time, current, interval, time, and current relative to the light, the digital tube is always bright, and the value of the display is the corresponding parameter value.
  • Parameter changeOperation indicator lights out, time, current, interval, time, current corresponding indicator light, digital tube flicker, and display value is corresponding parameter value change value.
  • Welding preparation: By [selection]/Adjust the encoder counter clockwise rotation,Make the running light bright, time,The current, interval, time, and current indicate the extinction of the lamp, and the welding can be carried out at this time. The value of the digital tube is the current welds value.
  • voltage calibration:Because this controller has the function of net pressure compensation, it is necessary to calibrate the voltage when the first time is installed, only one can be calibrated. (as long as the power transformer is not replaced, no recalibration is needed.)
  • Calibration operation:In running state, the lights that are kept on a micro motion until the time, the current and the interval are all lit up. At this time, the market voltage is measured by multimeter, for example, the voltage measured at that time is225VSo, the rotary encoder makes the value of the digital tube display225You can then double click the fretting switch and exit the calibration.

Parameter changes:

  • When querying parameters, by [selection]/Adjust the encoder to rotate, query, indicating the light, the digital tube shows the parameter values of the current corresponding parameters.
  • For example: rotation [choice]/In order to make the interval light bright, the value of the digital tube is the interval time.

Count zero:

  • This controller has the function of welding counting. In the process of welding, each welding, the welding count is added automatically.1. Counting range0-999.
  • If you want to clean up, when running, double click into/Preservation]Button, count automatic clear0.
trust seal
  • guaranteeQuality checked
  • Special gift cardsSpecial gift cards
  • Free return Within 60 days
  • Consultancy86-0755-85201155
Reference description:
  • Power supply: AC9-12V 3w 50HZ/60HZ (AC power must be used, DC power cannot be triggered)
  • Starting method: pedal or other passive normally open point (note that it must be a normally open point, and active signals cannot be used)
  • Triggering form: imported optocoupler for SCR
  • Display form: 0.56 digital tube
  • Adjustment method: encoder + button
  • Time range: 1-99
  • Current range: 300-999
  • Welding output: double pulse
  • Voltage stabilization function: Yes
  • Counting function: Yes
  • Power-off save: Yes
  • Number of standard groups: 1 group

Show state description:

  • Common control of the controller3Operation state, welding preparation, parameter query, parameter change
  • Welding preparation:Running light Always Time, current, interval, time, current indicating light out
  • Parameter query:The operation indicates the lights, time, current, interval, time, and current relative to the light, the digital tube is always bright, and the value of the display is the corresponding parameter value.
  • Parameter changeOperation indicator lights out, time, current, interval, time, current corresponding indicator light, digital tube flicker, and display value is corresponding parameter value change value.
  • Welding preparation: By [selection]/Adjust the encoder counter clockwise rotation,Make the running light bright, time,The current, interval, time, and current indicate the extinction of the lamp, and the welding can be carried out at this time. The value of the digital tube is the current welds value.
  • voltage calibration:Because this controller has the function of net pressure compensation, it is necessary to calibrate the voltage when the first time is installed, only one can be calibrated. (as long as the power transformer is not replaced, no recalibration is needed.)
  • Calibration operation:In running state, the lights that are kept on a micro motion until the time, the current and the interval are all lit up. At this time, the market voltage is measured by multimeter, for example, the voltage measured at that time is225VSo, the rotary encoder makes the value of the digital tube display225You can then double click the fretting switch and exit the calibration.

Parameter changes:

  • When querying parameters, by [selection]/Adjust the encoder to rotate, query, indicating the light, the digital tube shows the parameter values of the current corresponding parameters.
  • For example: rotation [choice]/In order to make the interval light bright, the value of the digital tube is the interval time.

Count zero:

  • This controller has the function of welding counting. In the process of welding, each welding, the welding count is added automatically.1. Counting range0-999.
  • If you want to clean up, when running, double click into/Preservation]Button, count automatic clear0.