10A Digital LCD Display Thermostat High precision Temperature Controller

10A Digital LCD Display Thermostat High precision Temperature Controller

SKU:X13137
Regular price $12.00 USD Sale price $8.99 USD

Description:
It is a digital temperature controller module. LCD display, very clear, easy to use, powerful. It can be widely used in smart homes, industrial control, automatic irrigation, indoor ventilation. Protect the device.
 
Feature:
LCD display
2. Power-down memory function
3. Emergency stop function
4. Display temperature in real time
5. Automatically save parameters
6. Support UART settings
7. Support heating and cooling modes
8. High temperature buzzer alarm
9. Work status indicator
10. Independent of parameters
11. Beautiful and practical
12. High precision
13. Display multiple parameters at the same time
 
Parameter:
1. Product Name: Digital Temperature Controller
2. Product Code: XY-WT01
3. Working voltage: DC 6V-30V
4. Control load current: 10A (maximum)
5. LCD refresh rate: 0.5 seconds
6. Temperature sensor: NTC-10K B3950
7. Test temperature: -50~110 °C
8. Control accuracy: 0.1 ° C
9. Sensor length: 0.5 m
10. Sensor probe specifications: 4 * 30mm stainless steel
11. Physical size: 79 * 44 * 26mm
12. Operating humidity: 5%~95% RH
 
Operating mode:
1. 'H': Heating mode.
When the current temperature value is less than the set temperature value - return temperature value, the relay will turn on and the heating device will start working.
When the current temperature value is greater than the set temperature value, the relay will be turned off and the heating device will stop working.
2. 'C': Cooling mode.
When the current temperature value is greater than the set temperature value + return temperature value, the relay will open and the cooling unit will start to work.
When the current temperature value is less than the set temperature value, the relay will be turned off and the cooling unit will stop working.
3. 'OPH': ON / OFF delayed start.
When the normal heating or cooling operation is completed, the system starts timing 'T'. The system will start the next round of heating or cooling only after 'T' > 'OPH'.
4. 'OFE': Temperature correction function (-10.0~10.0°C).
If the module works for a long time, there may be deviations. This function is corrected.
Actual temperature value = current temperature value + calibration value.
5. 'ALA': Set high temperature alarm.
When the current temperature value is greater than the set alarm temperature value, the module will turn on the audible and visual alarm and the relay will turn off. Any button stops the sound and light alarm.
 
Additional Features:
1. Set or read data via UART.
The startup temperature, stop temperature, temperature correction and other parameters can be set via the UART.
2. Temperature real-time report.
The module transmits the detected temperature to the terminal via the UART at 1 s intervals to facilitate data acquisition when the temperature reporting function is turned on.
3. Relay enabled (default on).
If the relay is enabled to turn off, the relay remains off.
In other words, the output state does not change regardless of the measured temperature.
4. Reset
Press the “STOP” and “SET” buttons simultaneously for more than 3 seconds to restore the factory settings.
 
Setting Parameters:
Long press: Press and hold the button for more than 3 seconds.
1. Set the working mode / set the temperature / return temperature value
1.1 Short press the “SET” button to enter the quick setup interface;
1.2 Switch the operating mode/set temperature/return temperature value by short pressing “SET”.
1.3 After selecting the parameters, press the “UP” or “DOWN” key to modify the parameter values. Support short press / long press;
1.4 Exit the quick setup interface and save the parameter for 3 seconds by long pressing the “SET” button or continue 6S without any button operation.
 
Note: The return temperature value is displayed in the first line of the current temperature value display position.
 
Set the temperature value to display the second line after "H" or "C".
2. Set OPH / OFE / ALA
2.1 Press and hold the “SET” button to enter the parameter setting interface.
2.2 Short press the “SET” button to switch the parameters that need to be set for OPH / OFE / ALA.
2.3 After selecting the parameters, press the “UP” or “DOWN” button to modify the parameter values. Support short press / long press;
2.4 Exit the parameter setting interface, long press the “SET” button to save the parameter for 3 seconds or continue 6S without any button operation.
2.5 How to turn on the high temperature alarm 'ALA' (default off). Select the 'ALA' interface and short press the 'STOP' button to turn "ALA" on or off. Set the high temperature value via the button 'UP' or 'DOWN' if 'ALA' is turned on. If the high temperature alarm function is off, 'ALA' displays '----' as a reminder. If 'ALA' is turned on, the LCD will display 'W'.
2.6 How to enable delayed start 'OPH' (default off). Select the 'OPH' interface and short press the 'STOP' button to turn 'OPH' on or off. If it is rotated, press the "UP" or "DOWN" button to set the delay time value ON'OPH'. If the delay star function is off, 'OPH' displays '----' as a hint. LCD will display 'h' on the last line, and the last bit will be displayed if delayed start is enabled.
 
Steps for usage:
1. Connect the NTC sensor to the digital temperature controller
2. Connect the voltage to the module
3. Setting parameters
4. Remove the input voltage
5. Connect the load
6. Connect the voltage to the module
 
Application:
Smart home
2. Industry
3. Automatic irrigation
4. Indoor ventilation
5. Homemade thermostatic control box
6. Equipment cabinet
7. Air conditioning system
8. Temperature control protection
9. Refrigerator
10. Freezer
11. Water heater
12. Moderator
13. Hatch control
 
Note:
It is a relay output mode and cannot be used as a power module. It cannot output voltage. The load needs to be connected to a separate power source.
 
Package:
1 XY-WT01 digital temperature controller
1 0.5m NTC-10K B3950 sensor
trust seal
  • guaranteeQuality checked
  • Special gift cardsSpecial gift cards
  • Free return Within 60 days
  • Consultancy86-0755-85201155
Description:
It is a digital temperature controller module. LCD display, very clear, easy to use, powerful. It can be widely used in smart homes, industrial control, automatic irrigation, indoor ventilation. Protect the device.
 
Feature:
LCD display
2. Power-down memory function
3. Emergency stop function
4. Display temperature in real time
5. Automatically save parameters
6. Support UART settings
7. Support heating and cooling modes
8. High temperature buzzer alarm
9. Work status indicator
10. Independent of parameters
11. Beautiful and practical
12. High precision
13. Display multiple parameters at the same time
 
Parameter:
1. Product Name: Digital Temperature Controller
2. Product Code: XY-WT01
3. Working voltage: DC 6V-30V
4. Control load current: 10A (maximum)
5. LCD refresh rate: 0.5 seconds
6. Temperature sensor: NTC-10K B3950
7. Test temperature: -50~110 °C
8. Control accuracy: 0.1 ° C
9. Sensor length: 0.5 m
10. Sensor probe specifications: 4 * 30mm stainless steel
11. Physical size: 79 * 44 * 26mm
12. Operating humidity: 5%~95% RH
 
Operating mode:
1. 'H': Heating mode.
When the current temperature value is less than the set temperature value - return temperature value, the relay will turn on and the heating device will start working.
When the current temperature value is greater than the set temperature value, the relay will be turned off and the heating device will stop working.
2. 'C': Cooling mode.
When the current temperature value is greater than the set temperature value + return temperature value, the relay will open and the cooling unit will start to work.
When the current temperature value is less than the set temperature value, the relay will be turned off and the cooling unit will stop working.
3. 'OPH': ON / OFF delayed start.
When the normal heating or cooling operation is completed, the system starts timing 'T'. The system will start the next round of heating or cooling only after 'T' > 'OPH'.
4. 'OFE': Temperature correction function (-10.0~10.0°C).
If the module works for a long time, there may be deviations. This function is corrected.
Actual temperature value = current temperature value + calibration value.
5. 'ALA': Set high temperature alarm.
When the current temperature value is greater than the set alarm temperature value, the module will turn on the audible and visual alarm and the relay will turn off. Any button stops the sound and light alarm.
 
Additional Features:
1. Set or read data via UART.
The startup temperature, stop temperature, temperature correction and other parameters can be set via the UART.
2. Temperature real-time report.
The module transmits the detected temperature to the terminal via the UART at 1 s intervals to facilitate data acquisition when the temperature reporting function is turned on.
3. Relay enabled (default on).
If the relay is enabled to turn off, the relay remains off.
In other words, the output state does not change regardless of the measured temperature.
4. Reset
Press the “STOP” and “SET” buttons simultaneously for more than 3 seconds to restore the factory settings.
 
Setting Parameters:
Long press: Press and hold the button for more than 3 seconds.
1. Set the working mode / set the temperature / return temperature value
1.1 Short press the “SET” button to enter the quick setup interface;
1.2 Switch the operating mode/set temperature/return temperature value by short pressing “SET”.
1.3 After selecting the parameters, press the “UP” or “DOWN” key to modify the parameter values. Support short press / long press;
1.4 Exit the quick setup interface and save the parameter for 3 seconds by long pressing the “SET” button or continue 6S without any button operation.
 
Note: The return temperature value is displayed in the first line of the current temperature value display position.
 
Set the temperature value to display the second line after "H" or "C".
2. Set OPH / OFE / ALA
2.1 Press and hold the “SET” button to enter the parameter setting interface.
2.2 Short press the “SET” button to switch the parameters that need to be set for OPH / OFE / ALA.
2.3 After selecting the parameters, press the “UP” or “DOWN” button to modify the parameter values. Support short press / long press;
2.4 Exit the parameter setting interface, long press the “SET” button to save the parameter for 3 seconds or continue 6S without any button operation.
2.5 How to turn on the high temperature alarm 'ALA' (default off). Select the 'ALA' interface and short press the 'STOP' button to turn "ALA" on or off. Set the high temperature value via the button 'UP' or 'DOWN' if 'ALA' is turned on. If the high temperature alarm function is off, 'ALA' displays '----' as a reminder. If 'ALA' is turned on, the LCD will display 'W'.
2.6 How to enable delayed start 'OPH' (default off). Select the 'OPH' interface and short press the 'STOP' button to turn 'OPH' on or off. If it is rotated, press the "UP" or "DOWN" button to set the delay time value ON'OPH'. If the delay star function is off, 'OPH' displays '----' as a hint. LCD will display 'h' on the last line, and the last bit will be displayed if delayed start is enabled.
 
Steps for usage:
1. Connect the NTC sensor to the digital temperature controller
2. Connect the voltage to the module
3. Setting parameters
4. Remove the input voltage
5. Connect the load
6. Connect the voltage to the module
 
Application:
Smart home
2. Industry
3. Automatic irrigation
4. Indoor ventilation
5. Homemade thermostatic control box
6. Equipment cabinet
7. Air conditioning system
8. Temperature control protection
9. Refrigerator
10. Freezer
11. Water heater
12. Moderator
13. Hatch control
 
Note:
It is a relay output mode and cannot be used as a power module. It cannot output voltage. The load needs to be connected to a separate power source.
 
Package:
1 XY-WT01 digital temperature controller
1 0.5m NTC-10K B3950 sensor